Published on
The F-gas regulation that applies in the Netherlands is Regulation (EU) 2024/573 on fluorinated greenhouse gases, together with Regulation (EU) 2024/590 on substances that deplete the ozone layer. Regulation 2024/573 restricts what you may place on the EU market: bans per equipment type, HFC quotas, labels and registration. Regulation 2024/590 prohibits ozone-depleting substances. MAAK Advocaten N.V., a law firm in Amsterdam, explains the roles in the supply chain.
In short
- Each equipment type has its own Annex IV ban date, and pre-charged equipment needs its HFCs accounted for in the quota system (Articles 11 and 19).
- The importer in the customs declaration is the undertaking registered in the F-gas Portal that holds quota or authorisations to use quota where the Regulation requires it (Article 23(2)).
- An importer of pre-charged equipment without an establishment in the Union needs an only representative established in the Union (Article 19(5)).
- Have a product law lawyer in the Netherlands review roles and contracts before you give a warranty or sign.
This article is part of our overview of EU sustainability regulations for products and of EU product law. It is written for manufacturers outside the EU that supply refrigeration, air-conditioning or heat pump equipment, or refrigerants, to Dutch or EU customers, and for the Dutch importers who receive them. It gives no UK, US or German advice.
What does the F-gas regulation cover in the Netherlands?
Regulation (EU) 2024/573 covers fluorinated greenhouse gases (F-gases) and the products and equipment that contain them or depend on them: containment, certification, bans on placing on the market, labelling, quotas for hydrofluorocarbons (HFCs), trade controls and reporting (Articles 1 and 2).
The Regulation entered into force on 11 March 2024 and replaced Regulation (EU) No 517/2014 (Articles 37 and 38). It applies directly to companies. In the Netherlands, Article 4 of the Besluit gefluoreerde broeikasgassen en ozonlaagafbrekende stoffen additionally prohibits acting contrary to the provisions of the Regulation listed there, and the Minister of Climate and Green Growth is the competent authority for the articles listed in Articles 3 and 7 of the Besluit.
“Placing on the market” does not mean selling in the Netherlands. It means release for free circulation in the Union, the first supply or making available to another person within the Union, or use of products or equipment manufactured for own use (Article 3, point 6). The F-gas Portal is not a Dutch register either: it is the Commission’s electronic system for quotas, licences and reporting (Article 20(1)).
| Role | What the text requires | Article |
|---|---|---|
| Importer named in the customs declaration | Holds quota or an authorisation to use quota where the Regulation requires it, and is registered in the F-gas Portal; registration number and EORI number in the declaration | Articles 20(4)(a), 23(2) and (3) |
| Manufacturer or importer of pre-charged equipment | HFCs in the equipment accounted for in the quota system; declaration of conformity | Article 19(1) and (2) |
| Importer without establishment in the Union | Appoints an only representative established in the Union with full responsibility | Article 19(5) |
| Producer or importer of HFCs | Holds a quota allocated by the Commission | Articles 16(1), 17(4) and 18(1) |
The Regulation does not define “importer”; for release for free circulation, the importer indicated in the customs declaration is the undertaking holding quota or authorisations to use quota as required under the Regulation and registered in the F-gas Portal (Article 23(2)). An only representative is not the authorised representative of CE marking or product safety law; for that role, see EU authorised representative in the Netherlands.
Which bans apply to cooling, air-conditioning and heat pump equipment?
Annex IV to Regulation 2024/573 lists the equipment that may no longer be placed on the market, and Article 11(1) prohibits it from the date given for each type. There is no single date: it depends on the equipment type, its capacity and the global warming potential (GWP) of the gas.
Three examples show the spread. Split air-to-water systems up to and including 12 kW with a gas of GWP 150 or more are banned from 1 January 2027, split air-to-air systems of that size from 1 January 2029, and split systems up to and including 12 kW with any F-gas from 1 January 2035 (Annex IV, point 9(b), (c) and (d)). Other points, for example for self-contained units and chillers, have their own dates (Annex IV, points 7 and 8). Where Annex IV excepts equipment needed to meet on-site safety requirements, the equipment must be labelled as being for use only where those requirements demand it (Article 12(15)).
Since 1 January 2025, the equipment listed in Article 12(1), including refrigeration, air-conditioning and heat pump equipment containing F-gases, may be placed on the market only if labelled. The label states the F-gas contained, its industry designation, the quantity by weight and in CO2 equivalent, and the GWP, in the official language or languages of the Member State where the equipment is placed on the market (Article 12(1), (3) and (4)).
The Commission can, at the reasoned request of a Member State authority, grant an exception of up to four years (Article 11(5)). Implementing Regulation (EU) 2026/2486 does so for certain indoor monoblock heat pumps, and only if they are labelled under Article 12(2) of Regulation 2024/573 (Article 1). It enters into force on 1 December 2026 and applies from 1 January 2027 to 31 December 2027 (Article 2).
Stock needs a date check. For one year following each Annex IV date, the further supply of equipment lawfully placed on the market before that date is allowed only if you can show that it was placed on the market lawfully before that date (Article 11(1), last subparagraph).
My first step is to establish per batch what was placed on the market when; that is in your records and your customs declarations. Then you decide per batch whether to keep it, sell it or take it back. That way you do not write off healthy stock, and you have a file if the authority asks. I would never put “old stock” in a contract without a date and a batch number.
How do quotas work, and what does an importer of pre-charged equipment need?
Quotas under Articles 16 to 19 limit the quantity of HFCs that may be placed on the market. They are allocated to producers and importers of HFCs (Articles 16(1) and 17(4)). Importers of pre-charged equipment fall under Article 19 instead.
Under Article 19(1), refrigeration and air-conditioning equipment and heat pumps pre-charged with HFCs may not be placed on the market unless the HFCs in them are accounted for within the quota system. Manufacturers and importers document this and draw up a declaration of conformity, which they keep for at least five years. By drawing it up they assume responsibility for compliance (Article 19(2)).
If the HFCs in the equipment were not placed on the market before the equipment was charged, importers also have the documentation, the declaration and their report verified every year by an independent auditor registered in the F-gas Portal (Article 19(3)). Article 19 does not apply to undertakings that place less than 10 tonnes of CO2 equivalent of HFCs per year in such equipment on the market (Article 19(6)).
An importer without an establishment in the Union must appoint an only representative with an establishment in the Union, who assumes full responsibility for complying with the Regulation (Article 19(5)). The same applies to bulk gases (Article 11(8)) and to quotas (Article 18(1)). A company established in the Union that is the importer does not need one; a manufacturer outside the Union that imports itself does.
The agreement that makes the most difference is which party is named as importer in the customs declaration, who therefore arranges the registration and the declaration, and who supplies the data. I put the allocation of roles in one short paragraph that you can use in the next contract round. I leave longer clauses out of this article; we write them together once the roles are fixed. My proposal is the Dutch importer or distributor as importer of record, which handles registration, declaration and checks, while the foreign manufacturer supplies the data. That is simplest if it is a party established in the Union.
What do the ozone-depleting substances rules add?
Regulation (EU) 2024/590 prohibits the production, placing on the market, supply, use, import and export of the ozone-depleting substances in its Annex I (Article 4), and the placing on the market, supply, import and export of products and equipment that contain them or depend on them (Article 5), except for the exceptions in Articles 6 to 14.
Permitted imports and exports, for example for feedstock or laboratory use, need a licence from the Commission’s licensing system (Articles 13(2), 14(3) and 16). An undertaking without an establishment in the Union appoints an only representative established in the Union (Article 16(3)). Halon fire protection is prohibited, apart from critical uses, and equipment containing such substances is dismantled at the end of its life (Article 11(2) and (3)). The Dutch counterpart of Article 4 is Article 8 of the Besluit.
How are the F-gas rules enforced in the Netherlands?
In the Netherlands, the competent authority under Articles 3 and 7 of the Besluit is the Minister of Climate and Green Growth, for the articles of the Regulations listed there. Which body acts in a given case, and with which instrument, we assess per file. Member States set the penalties (Article 31 of Regulation 2024/573; Article 27 of Regulation 2024/590).
If the authority asks for a declaration or for data, I first read what exactly is requested, about which equipment and which period. Then we gather the documents: the declaration of conformity, the documentation of the quantity of gas, the label, the customs declaration with the registration number, and the agreements with your partners in the chain. I reply on behalf of the company with what exists and say what we are still looking into. If something is not in order, we set out in the same letter how and when it will be remedied; that works better than a late, incomplete reply. If a decision or order follows, we prepare the written view (zienswijze) together and monitor the objection and appeal periods.
What can you arrange yourself?
Looking up the refrigerant per model, producing the label and registering in the F-gas Portal are administrative and technical work (Articles 12 and 20(4)).
A company comes to me with: “We want to import heat pumps or cooling equipment, and our supplier says it is F-gas proof.” Or the reverse: a customer asks for a declaration of conformity and the company does not know which one. My first step is not the gas but the model: which type of equipment, which capacity, which refrigerant, and when it is placed on the market. We put that on paper in an hour. Then you know which date in the Regulation applies to that equipment, who carries the duties and what you need for the customs declaration.
Looking up the refrigerant of a model, having the label made and registering in the portal you arrange yourself or with a compliance adviser. You need a lawyer when it is about role, contract or the authority: you want to know who in your chain carries the duties for pre-charged equipment, your customer puts the declaration of conformity and its consequences on you, you receive a question from the authority, or you have shipped to parties where you now have doubts. Do not wait until a letter lands on your desk.
What suppliers outside the EU often get wrong about the Netherlands is the assumption that the duties travel with the equipment, and that a label and a datasheet for the Dutch customer are enough. Whoever is named as importer in the customs declaration must be registered in the Commission’s F-gas Portal, and an importer without an establishment in the Union needs an only representative in the Union for pre-charged equipment (Articles 20(4) and 19(5)). My advice: decide before the first shipment who is the importer and who carries the declaration, have the label made in an official language of the Member State where the equipment is placed on the market (Article 12(4)), and record the allocation of roles in the contract with your Dutch partner.
This article does not cover the certification of installers and technicians (Article 10 of the Regulation; Article 6 of the Besluit).
When do you need a Dutch lawyer for the F-gas rules?
You need one when the question is who carries the duty in your chain, what a contract says, or what the authority asks. The role decides who must register, declare and report (Articles 19, 20 and 23 of Regulation 2024/573).
| Your situation | What is at stake | Why a lawyer, not only a technical adviser | What we do in the first days |
|---|---|---|---|
| A Dutch importer asks whether your equipment may still be placed on the EU market | Whether a ban or the quota system applies and who answers for it (Articles 11 and 19) | The technical check shows whether the product meets the Annex; the lawyer decides who bears the risk and what you sign | Assess your role, review the supply contract, propose how risk is allocated |
| A Dutch customer wants a compliance warranty or indemnity | Contractual liability for the declaration of conformity (Article 19(2)) | The wording of warranty and recourse decides who pays | Review terms and propose counter-wording |
| Customs or the Dutch authority asks for documents | Administrative enforcement in the Netherlands (Article 4 Besluit) | Answering an authority is legal work with deadlines | Assess the documents, contact the authority, prepare the reply or an objection |
| Stock falls under a new ban | What may still be supplied (Article 11(1)) | Sell-off terms and contract clauses | Define the position, agree terms with customers and suppliers |
How does MAAK Advocaten work on F-gas matters?
We act for manufacturers outside the EU and for their Dutch importers and distributors: role analysis, contracts under Dutch law, contact with the authority, and objection and appeal in the Netherlands. The technical work, such as the label, the gas data and the registration in the F-gas Portal, stays with you or your compliance adviser.
Frequently asked questions about the F-gas regulation in the Netherlands
Does the F-gas regulation apply to my equipment if I am based outside the EU?
Regulation (EU) 2024/573 applies to equipment placed on the market in the Union, for example released for free circulation or first supplied within the Union (Article 3, point 6). The bans in Annex IV and the label requirement in Article 12 apply to that equipment. Which party carries which duty depends on its role in the chain, for example as importer named in the customs declaration or as only representative.
Do I need a quota to import heat pumps or cooling equipment?
Quotas are allocated to producers and importers of HFCs (Articles 16(1) and 17(4)). An importer of pre-charged equipment instead must make sure that the HFCs in it are accounted for within the quota system and draw up a declaration of conformity (Article 19(1) and (2)). Which route applies to you depends on your role and your product.
Do I need an only representative in the Union?
An importer of pre-charged equipment without an establishment in the Union must appoint an only representative with an establishment in the Union, who assumes full responsibility for complying with the Regulation (Article 19(5)). The same applies to bulk gases (Article 11(8)) and to quotas (Article 18(1)). A company established in the Union that is the importer does not need one; a manufacturer outside the Union that imports itself does.
From which date are split heat pumps banned?
There is no single date. Under Annex IV, point 9, split air-to-water systems up to 12 kW with a gas of GWP 150 or more are banned from 1 January 2027, split air-to-air systems of that size from 1 January 2029, and split systems up to 12 kW with any F-gas from 1 January 2035, in each case except where on-site safety requirements demand otherwise. Implementing Regulation (EU) 2026/2486 will allow an exception for two types of indoor monoblock heat pumps from 1 January 2027 to 31 December 2027.
When should a manufacturer outside the EU call a Dutch lawyer about F-gases?
When a Dutch importer or customer asks for a declaration of conformity, a warranty or an indemnity, when customs or the Dutch authority asks for documents, or when stock falls under a new ban date. Have a product law lawyer in the Netherlands review the roles and the contract first; we review both.
Primary sources
- Regulation (EU) 2024/573 (F-gas regulation): Articles 1 to 3, 10 to 12, 16 to 20, 23, 31, 37 and 38 and Annex IV, with corrigendum of 24 March 2025
- Regulation (EU) 2024/590 (substances that deplete the ozone layer): Articles 4 to 6, 11, 13, 14, 16 and 27
- Implementing Regulation (EU) 2026/2486: exception for certain indoor monoblock heat pumps
- Besluit gefluoreerde broeikasgassen en ozonlaagafbrekende stoffen, version of 18 August 2025: Articles 3, 4, 6, 7 and 8
Do you supply cooling, air-conditioning or heat pump equipment to the Netherlands from outside the EU, and is it unclear who carries the F-gas duties? Put your situation to Martin Krüger, our product law partner in the Netherlands.